Page view 29
2.6.4 Further messages
The following messages are intended for information on the status of
the D6. They are no error messages.
Standby: indicates that the device is in standby mode.
Unlock: Press knob 2s: indicates that the device has been locked
to protect it against accidental or unauthorized operation. Press and
hold the encoder for a minimum of 2 seconds until "Lock" disappears
from the lower status line of the LCD.
2.7 System Reset
Note:
Following a system reset operation all user settings of the device are
lost except for the "dbCAN Id".
- Switch off the unit.
- Press and hold down the MUTE A switch while switching on the
power supply to the unit again.
The following "Reset screen" is displayed:
All Settings have been
reset to factory defaults
Press A again to reboot
dbCAN active Id 0.01
- Release the MUTE A switch and press the MUTE A switch again.
The unit will restart and is ready for operation.